The following settings are available in the Topology Editor, however changing them will not make any difference to the installation.

Discovery Server

ELEMENT_THREAD - Hardcoded in datachannel

SUBELEMENT_THREAD - Hardcoded in datachannel

1.3.0 to 1.3.1. topology editor issues

While upgrading TNPM Wireline 1.3.0 -> TNPM Wireline 1.3.1, can not load the 1.3.0 Topology from database into the 1.3.1 Topology Editor. Symptom

'Finish' button never becomes selectable Diagnosing the problem

Confirm whether the 1.3.0 Topology Editor was uninstalled prior to installing the 1.3.1 Topology Editor or whether the 1.3.1 Topology Editor was installed on top of it. Resolving the problem

(1) If you overlooked the Topology Editor uninstall / reinstall step, listed in the 'About this task' section of the 'Installing and starting the Topology Editor' section of the TNPM Wireline 1.3 to 1.3.1 Upgrade Guide, do the following:

   Make a backup of your <TopologyEditor>/metadata/appPacks directory
   Follow the steps in the 1.3.1 Install Guide for uninstalling & reinstalling the Topology Editor
   Restore the contents of your <TopologyEditor>/metadata/appPacks directory
   Try again to load your 1.3.0 Topology from database


(2) If you performed the Topology Editor uninstall / reinstall step and had bulk TechPacks installed but did not restore your backed up <TopologyEditor>/metadata/appPacks/*.xsd files, do the following:

   Restore your *.xsd files
   Try again to load your 1.3.0 Topology from database


(3) Make sure that the database credentials you are using to connect to your TNPM Wireline 1.3.0 database are correct